{"id":1633,"date":"2016-08-30T10:26:35","date_gmt":"2016-08-30T17:26:35","guid":{"rendered":"https:\/\/live-optics-wp.pantheonsite.io\/milster\/?page_id=1633"},"modified":"2016-11-03T10:57:19","modified_gmt":"2016-11-03T17:57:19","slug":"mo-settings-panel","status":"publish","type":"page","link":"https:\/\/wp.optics.arizona.edu\/milster\/resources\/optiscan-simulation-program\/optiscan-help-desk\/index\/mo-settings-panel\/","title":{"rendered":"MO Settings Panel"},"content":{"rendered":"<p>The <em>MO Settings Panel<\/em> allows you to modify the general parameters used in the MO ( Magneto-Optical Target ) calculation.<\/p>\n<hr \/>\n<h3>MO Index Settings:<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1362\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/mo_index_settings.jpg\" alt=\"mo_index_settings\" width=\"515\" height=\"21\" data-id=\"1362\" srcset=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/mo_index_settings.jpg 515w, https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/mo_index_settings-300x12.jpg 300w\" sizes=\"auto, (max-width: 515px) 100vw, 515px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1460\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/nincident-1.gif\" alt=\"nincident\" width=\"234\" height=\"29\" data-id=\"1460\" \/>\u00a0&#8211; The index of refraction for incident material<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1462\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/nsubstrate-1.gif\" alt=\"nsubstrate\" width=\"234\" height=\"27\" data-id=\"1462\" \/> &#8211; The index of refraction for substrate<\/p>\n<hr \/>\n<h3>MO General Parameters:<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1361\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/mo_general_parameters.jpg\" alt=\"mo_general_parameters\" width=\"523\" height=\"20\" data-id=\"1361\" srcset=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/mo_general_parameters.jpg 523w, https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/mo_general_parameters-300x11.jpg 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1367\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/z0.jpg\" alt=\"z0\" width=\"240\" height=\"25\" data-id=\"1367\" \/>\u00a0&#8211; The amount of defocus in the z-axis<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1359\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/exy.jpg\" alt=\"exy\" width=\"240\" height=\"30\" data-id=\"1359\" \/>\u00a0&#8211; Off-diagonal element of permittivity<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1469\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/ZOFFSET.gif\" alt=\"ZOFFSET\" width=\"234\" height=\"26\" data-id=\"1469\" \/>\u00a0&#8211; The amount of offset from the interface in the z-axis<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1360\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/interface.jpg\" alt=\"interface\" width=\"238\" height=\"25\" data-id=\"1360\" \/>\u00a0&#8211; The top position of each layer in the z-axis<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-1463\" src=\"https:\/\/wp.optics.arizona.edu\/milster\/wp-content\/uploads\/sites\/48\/2016\/08\/resultfield-1.gif\" alt=\"resultfield\" width=\"142\" height=\"85\" data-id=\"1463\" \/><br \/>\n<strong>Pupil<\/strong> &#8211; Observe the electric field at the exit pupil<br \/>\n<strong>Image<\/strong> &#8211; Observe the electric field at the optical disk<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The MO Settings Panel allows you to modify the general parameters used in the MO ( Magneto-Optical Target ) calculation. MO Index Settings: \u00a0&#8211; The index of refraction for incident material &#8211; The index of refraction for substrate MO General Parameters: \u00a0&#8211; The amount of defocus in the z-axis \u00a0&#8211; Off-diagonal element of permittivity \u00a0&#8211; The amount of offset from<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":894,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1633","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/pages\/1633","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/comments?post=1633"}],"version-history":[{"count":3,"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/pages\/1633\/revisions"}],"predecessor-version":[{"id":2010,"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/pages\/1633\/revisions\/2010"}],"up":[{"embeddable":true,"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/pages\/894"}],"wp:attachment":[{"href":"https:\/\/wp.optics.arizona.edu\/milster\/wp-json\/wp\/v2\/media?parent=1633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}